Key Features
- Model: Liebert GXT MT+EX
- Power Output Capacity: 3KVA/2700 W
- Input Voltage: 230 Vac
- Battery Type: 12V/9Ah (6 units)
- Features: Battery Mode, Low Battery, Overload and Fault Alarm
Specification
Main Feature | ||
Capacity | 3000VA | |
Display Type | LCD Display | |
Load Capacity | 2700 W | |
Input Voltage | Nominal Voltage: 230 Vac Low Line Transfer (Voltage Range): 180 Vac/160 Vac/140 Vac/120 Vac ± 5% (Ambient Temperature < 35 °C) (Based on load percentage 100% to 80%; 80% to 70%; 70% to 60%; 60% to 0%) Low Line Comeback (Voltage Range): 195 Vac/175 Vac/155 Vac/145 Vac ± 5 % (Ambient Temperature < 35 °C) (Based on load percentage 100% to 80%; 80% to 70%; 70% to 60%; 60% to 0%) High Line Transfer (Voltage Range): 300 Vac ± 5% High Line Comeback (Voltage Range): 290 Vac ± 5% Frequency Range: 40 Hz to 70 Hz Power Factor: ≥ 0.99 @ 100% load |
|
Output Voltage | Nominal Voltage” 208* Vac/220 Vac/230 Vac/240 Vac AC Voltage Regulation: ± 1% Frequency Range (Synchronized Range): (47 Hz to 53 Hz) or (57 Hz to 63 Hz) |
|
Frequency (Battery Mode) | (50 Hz ± 0.25 Hz) or (60 Hz ± 0.3 Hz) | |
Noise Level | Less than 50 dBA @ 1 meter (m) | |
Battery | Battery Type (Standard Run Model): 12 V/9 Ah Numbers (Standard Run Model): 6 Typical Recharge Time (Standard Run Model): 4 hours recovery to 90% capacity (Typical) Charging Current (maximum) (Standard Run Model): 1.0 A Charging Voltage (Standard Run Model): 82.1 Vdc ± 1% Battery Type (Long Run Model): Depending on the capacity of external batteries Numbers (Long Run Model): 6 Charging Current (Long Run Model): 1.0 A/2.0 A/4.0 A/6.0 A (6.0 A by default) Float Charging Voltage (Long Run Model): 82.1 Vdc ± 1% |
|
Alarm | Battery Mode: Sounding every 4 seconds Low Battery: Sounding every second Overload: Sounding twice every second Fault: Continuously sounding |
|
Indications | LCD: Panel UPS status, load level, battery level, input/output voltage, discharge timer, and fault conditions | |
Others | Environment: Operation Humidity and Temperature: 20% to 90% RH @ 0 °C to 50 °C** (non-condensing) Noise Level: Less than 50 dBA @ 1 meter (m) Management: Smart RS232/USB: Supports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC |
|
Input Features | ||
Frequency | 40 to 70 Hz | |
Power Factor | ≥ 0.99 @ 100% load | |
Voltage Range | Low Line Transfer (Voltage Range): 180 Vac/160 Vac/140 Vac/120 Vac ± 5% (Ambient Temperature < 35 °C) (Based on load percentage 100% to 80%; 80% to 70%; 70% to 60%; 60% to 0%) Low Line Comeback (Voltage Range): 195 Vac/175 Vac/155 Vac/145 Vac ± 5 % (Ambient Temperature < 35 °C) (Based on load percentage 100% to 80%; 80% to 70%; 70% to 60%; 60% to 0%) High Line Transfer (Voltage Range): 300 Vac ± 5% |
|
Output Features | ||
Voltage Range | 208 Vac/220 Vac/230 Vac/240 Vac | |
Type of Wave | Pure Sine wave | |
Transfer Time | Transfer Time: Bypass to Inverter (Line mode): Zero Transfer Time: Inverter to Bypass (Line mode): 4 millisecond (ms) (Typical) |
|
Physical Specification | ||
Dimension | (Standard Run Model) Dimension, D x W x H (mm): 421 x 190 x 318 (Long Run Model) Dimension, D x W x H (mm): 397 x 145 x 220 |
|
Weight | (Standard Run Model) Net Weight (kg): 27.6 (Long Run Model) Net Weight (kg): 7.4 |
|
Manufacture Warranty | ||
Warranty | 1 Year (UPS), 6 Months (Battery) |